Company :shenzhen polymer batter co.,ltd
Contacts:cao shen
Tel: +86-755-36631197
Fax: +86-755-61658083
Mob: 18681564491
e-mail:janson@polymer-batterys.com
Address: 2 floor, east red industrial 2, 8 Yuli Road, Guanlan Niu lake, Longhua New District, Shenzhen, Guangdong
In charge of matters needing attention
(一)View the explosion-proof battery electrolyte
When low amounts of electrolyte, stop using the forklift。
①the amount of electrolyte is not at the time, can cause the battery overheat, serious when, can make the battery and combustion forklift electronic components。
②Check the amount of electrolyte, once a week when low amounts of electrolyte, compensate for refined water to the specified amount。
(二)To prevent excessive charging
(三)Guard against electric shock
When charging, the charger has high voltage and energy, so stop touching the battery while the charge is negative or transformer。
(四)Charging in ventilation outstanding places
① When charging, the battery will produce explosive gas; So need to charge in concession and ventilation outstanding places.。
② When the forklift truck is equipped with other varieties of (GS) of the battery, in accordance with the manufacturer's instructions.
(五)Check the wiring and socket before charging, check the wiring and socket; When lines or socket is damaged, can't charge.
(六) Check before charging proportion, check the proportion of each unit.
(七)STOP charging when STOP charging, explosion-proof battery first press STOP on the charger (STOP), to remove the plug. If he does not abide by the lead to get an electric shock or battery flash fire, explosion.
(八)The charging method
There are three kinds of charging ways: charge, equal charge and compensate for electricity. The moment, the charge will be paid by resolution power shortage situation and battery capacity. General situation, filled with a battery should be 8 to 10 hours.
三、The charger
①Use additional fuse. When replace the charger fuse, first remove the input and output plugs.
②The change of the power supply must be additional input range of plus or minus 10%。
③The charger shall be used under 0 ℃ to 40 ℃ environment. When the environment temperature is higher than 40 ℃, can lead to charge is overheating.
④Stop recharged in high temperature places (such as rain and snow and local). Otherwise can cause a short circuit or burning.
⑤Cannot be used for other charge. Charger planning, only suitable for forklift charging.
⑥Regularly check the charger wire and plug. Explosion-proof battery when lines or socket is damaged, please do not use the charger.
⑦Using the line to ground. Otherwise there is risk of electric shock。
⑧Stop the modification or remove the charger.
⑨Stop using the charger to multiple rechargeable battery for continuity. Or it will lead to overheating, so that damage to the charger.